- Home
- /Products
- /Passenger car repair equipment
- /Underfloor generator repair and test station
Underfloor generator repair and test station
Integrated electrical shop station: a tilter for disassembly and assembly of underfloor generators and a test rig for checking them under load after repair.
We will send photos and drawings of the equipment on request via the contacts page.
Equipment
Description
The station combines workplaces for the complete repair cycle of passenger car underfloor generators — DC and AC machines rated up to 35 kW, including the generators of air-conditioned cars. Disassembly, inspection, bearing replacement, assembly and final load testing with a test report are all carried out in one area.
The repair part is built around a tilter with an electromechanical rotation drive: a generator weighing up to 1200 kg is clamped by its feet or flange and rotated through 360° with locking every 90°, giving access to the bearing end shields, commutator or slip rings and terminal box without re-slinging. Next to it are a table with a hydraulic press for pressing bearings off and on, and a rack for storing assemblies in disassembly order.
The test rig drives the generator from an electric motor through a V-belt transmission with a tensioner; the speed is set by a frequency converter across the whole working range, including the minimum excitation speed. The load bank — a sectional resistor block with forced cooling — loads the generator in steps up to rated power. The measuring system records voltage, current, speed, winding and bearing temperatures and the excitation cut-in point; the results are written to the test report.
The station is configured for the customer's range of generators: adapter plates for different flanges, pulleys for the standard sizes, fixtures for winding insulation checks and rotor balancing. Individual modules — the tilter or the test rig — can be supplied separately.
Features
Design features
- Tilter locked every 90° — The electromechanical drive rotates the generator without jerks; a stop holds the rotor and housing in any of the four positions.
- Full-load testing — A fan-cooled resistor block absorbs the rated power of the generator in continuous operation.
- Full speed range — The frequency converter allows checking the cut-in speed and the operation of the voltage regulator at minimum and maximum speed.
- Test report — Measured values are recorded against the generator serial number and stored in the rig archive.
- Bearing press — A hydraulic press with a set of mandrels eliminates impact fitting and damage to bearing seats.
- Modular delivery — The tilter, press and test rig are supplied together or separately to suit the existing layout of the electrical shop.
Specifications
Technical specifications
| Parameter | Value |
|---|---|
| Power of generators under test, kW | up to 35 |
| Generator weight on the tilter, kg | up to 1200 |
| Tilter rotation angle | 360°, locked every 90° |
| Test rig drive motor power, kW | 45 |
| Generator speed, rpm | 300–4000 |
| Load bank power, kW | 40 |
| Voltage of generators under test, V | 50–150 |
| Press force, kN | 100 |
| Power supply | 3×380 V, 50 Hz |
| Installed power of the station, kW | 60 |
| Floor area, m² | 36 |
| Equipment weight, kg | 5200 |
The composition of the station and the load bank power are determined by the list of generators repaired at the customer's depot.
Section
Other equipment in this section
Request a commercial proposal and lead time
Send us your technical assignment or specify the rolling stock series — we will prepare a quotation within one business day.
