1. Home
  2. /Products
  3. /Equipment for locomotive service points
  4. /Inspection pit equipment set for locomotive service points

Inspection pit equipment set for locomotive service points

Lighting, compressed air and power distribution, ladders and guards for an inspection pit, configured to the length and profile of the pit at a specific service point.

Photos on request

We will send photos and drawings of the equipment on request via the contacts page.

Equipment

Description

The set is intended for outfitting inspection pits at locomotive service points where the running gear, brake rigging, traction motors and underfloor equipment are examined. Its task is to give the fitter light, compressed air and power at any point of the pit and to provide safe descent and movement beneath the locomotive.

The set is built from 6 m sections, each containing LED luminaires on a safe 36 V supply, cable ducts, 24 V and RCD-protected 220 V sockets and brackets for hanging tools. Air outlets with hose reels connected to the site's compressed air network are installed every 12 m. Access to the pit is by fixed ladders with anti-slip treads; pit ends and open areas are closed with removable guards.

Lighting is fed from a 380/36 V step-down transformer housed in a cabinet on the pit wall or in a separate recess. All components are made of galvanized steel with stainless fasteners and are rated for a damp environment, vibration and exposure to oil. On request the set includes pit trolleys for inspection, lubricant distribution lines, emergency lighting and drainage channels.

Features

Design features

  • Safe voltage — Lighting and hand lamps run on 36 V and 24 V, and the 220 V sockets are RCD-protected — working in a damp pit requires no additional measures against electric shock.
  • Modular layout — 6 m sections are assembled into a pit of any length; when the site is rebuilt, the set is extended with new sections without replacing existing ones.
  • Air and power where needed — Hose reels and sockets are placed so that the fitter never drags a hose more than 6 m from the connection point.
  • Resistant to the pit environment — Galvanized steel, stainless fasteners and IP65-rated luminaires withstand moisture, oil and constant vibration.
  • Ready for installation — Fasteners, embedded parts and wiring diagrams are supplied with the set; installation proceeds without shutting down adjacent pits.

Specifications

Technical specifications

ParameterValue
Length of outfitted pit60–120 m (per project)
Mounting section length6 m
Pit lighting voltage36 V
Illuminance in the working area150 lx minimum
Lighting power per section0.15 kW
Sockets in each section24 V and 220 V
Air outlet spacing12 m
Compressed air pressure0.6–0.8 MPa
Hose reel length15 m
Ingress protection of luminaires and socketsIP65
Step-down transformer supply3×380 V, 50 Hz
Weight of a 6 m sectionapprox. 160 kg
Operating temperature−20…+40 °C

The set composition and number of sections are determined from pit measurements and the customer's specification.

Request a commercial proposal and lead time

Send us your technical assignment or specify the rolling stock series — we will prepare a quotation within one business day.

Request a proposal